Menü überspringen

TS 444/TS 642/ TS 740

Infrared

Workpiece touch probe

TS 444

TS 642

TS 740

Probe accuracy

±5 µm when using a standard T404 stylus

±1 µm when using a standard T404 stylus

Probe repeatability

Repeated probing from one direction

2 σ 1 µm at a probing velocity of 1 m/min

Typical values:

2 σ 1 µm at a probing velocity of 3 m/min

2 σ 4 µm at a probing velocity of 5 m/min

2 s 0.25 µm
at a probing velocity of 0.25 m/min

Deflection of probe contact

5 mm in all directions (with stylus length L = 40 mm)

Deflection force

Axial: approx. 8 N

Radial: approx. 1 N

Axial: approx. 0.6 N

Radial: approx. 0.2 N

Probing velocity

5 m/min

0.25 m/min

Protection EN 60 529

IP67

Operating temperature

10 °C to 40 °C

Storage temperature

–20 °C to 70 °C

Mass without taper shank

Approx. 0.4 kg

Approx. 1.1 kg

Fastening*

With taper shank* (overview on page 18)

Without taper shank (connecting thread M12 x 0.5)

Without taper shank (connecting thread M30 x 0.5)

Signal transmission

Infrared transmission with 360° range

Transmission angle of infrared signal*

0° or +30°

Transmitter/receiver unit*

SE 540 or SE 642

SE 540, SE 642 or SE 660 (infrared only)

SE 540 or SE 642

TS switch-on/off

Infrared signal from SE

Via switch in the taper shank or infrared signal from SE

Infrared signal from SE

Energy supply/
voltage supply

Compressed air
Recommended operating pressure
5.5 · 105 to 8 · 105 Pa

Batteries, rechargeable or nonrechargeable

Energy buffer

Integrated high-power capacitors,
charging time typically 3s at 5.5 · 105 Pa

Two rechargeable or nonrechargeable batteries, 1 V to 4 V each, size C or size A1)

Operating time

Typically 120 s

Typically 800 h2)
(reduced operating time as replacement for TS 632)

Typically 500 h2)

* Please select when ordering

1) Via adapter, included in delivery

2) In continuous operation with 3.6 V/6000 mAh lithium batteries; with the size A lithium batteries included in delivery, only half the service life is reached

105 Pa 1 bar