LIC 4119 / LIC 4199

    Specifications

    Scale

    LIC 4009

    Measuring standard

    Coefficient of linear expansion

    Steel scale tape with absolute and incremental METALLUR track

    αtherm  10 · 10–6 K–1

    Accuracy grade*

    ±3 µm, ±15 µm1)

    Baseline error

    ±0.750 µm/50 mm (typical)

    Measuring length (ML)*
    in mm

    70 120 170 220 270 320 370 420 520 620 720 820 920 1020

    Mass

    31 g/m

    Scanning head

    LIC 411

    LIC 419 F

    LIC 419 M

    LIC 419 P

    LIC 419 Y

    Interface

    EnDat 2.2

    Fanuc Serial Interface αi

    Mitsubishi high speed interface

    Panasonic Serial Interface

    Yaskawa Serial Interface

    Ordering designation*

    EnDat22

    Fanuc05

    Mit03-4

    Mit02-2

    Pana01

    YEC07

    Measuring step*

    0.01 µm (10 nm)

    0.005 µm (5 nm)

    0.001 µm (1 nm)2)

    Calculation time tcal

    Clock frequency

    5 µs

    16 MHz

    Traversing speed3)

    600 m/min

    Interpolation error

    ±20 nm

    Electrical connection*

    Cable, 1 m or 3 m, with 8-pin M12 coupling (male) or 15-pin D-sub connector (male)

    Cable length (with HEIDENHAIN cable)

    100 m4)

    50 m

    30 m

    50 m

    Supply voltage

    DC 3.6 V to 14 V

    Power consumption3) (max.)

    At 3.6 V: 700 mW

    At 14 V: 800 mW

    At 3.6 V: 850 mW

    At 14 V: 950 mW

    Current consumption (typical)

    At 5 V: 75 mA
    (without load)

    At 5 V: 95 mA (without load)

    Vibration 55 Hz to 2000 Hz

    Shock 6 ms

    500 m/s2 (EN 60068-2-6)

    1000 m/s2 (EN 60068-2-27)

    Operating temperature

    –10 °C to 70 °C

    Mass Scanning head

    Connecting cable

    Connecting element

    18 g (without cable)

    20 g/m

    M12 coupling: 15 g; D-sub connector: 32 g

    * Please select when ordering

    1) ±5 µm after linear length-error compensation in the evaluation electronics

    2) Mitsubishi: measuring length 2040 mm

    Yaskawa: measuring length 1840 mm

    3) See General electrical information in the Interfaces of HEIDENHAIN Encoders brochure

    4) With LIC 411 FS scanning head: clock frequency: 8 MHz